Reuven — Engineering Calculation Suite

Engineering Tools

Professional calculators for facade, structural, and building performance engineering — standards-based, transparent, and free to use.

176Calculators
14Disciplines
StandardsBased
FreeNo Sign-Up

Structural

31 Tools
Structural

Structural Analyzer

Static and dynamic structural analysis with FEM, 3D visualization, and comprehensive reporting.


FEM AnalysisLoad Cases3D Visualization
Structural

Wind Load Calculator

Wind pressure analysis per ASCE 7-22, Eurocode 1, and AS/NZS 1170.2.


ASCE 7-22Eurocode 13-Code Comparison
Structural

Seismic Load Calculator

Seismic base shear, story force distribution, and design response spectrum using the Equivalent Lateral Force method.


ASCE 7-22 / EC8 / AS 1170.4ELF MethodDesign Spectrum
Structural

Steel Connection Calculator

Steel connection design with bolt shear, bearing, weld capacity, block shear, and net section checks for fin plate, end plate, base plate, and bracing gusset connections.


Bolt & Weld Design4 Connection TypesEC3/AISC/AS 4100
Structural

RC Beam & Column Design

Reinforced concrete flexural and shear design with reinforcement calculation, interaction diagrams, and crack width checks.


Eurocode 2ACI 318Auto Bar Selection
Structural

Steel Member Design

Steel beam and column capacity checks with moment, shear, buckling, and combined interaction analysis.


EC3/AISC 36030 SectionsLTB Check
Structural

Timber Design Calculator

Timber beam, column, and joist sizing with bending, shear, bearing, and deflection checks.


EC5/NDS16 GradesModification Factors
Structural

Load Combination Generator

Generate all factored ULS and SLS load combinations with governing case identification.


Eurocode 0ASCE 7 LRFD/ASDGoverning Case
Structural

Slab Design Calculator

One-way, two-way, and flat slab design with punching shear and deflection checks.


EC2/ACI 318Punching ShearOne-way/Two-way
Structural

Masonry Wall Design

Vertical and lateral load capacity with slenderness and eccentricity checks for load-bearing masonry.


EC6/TMS 402SlendernessLateral Resistance
Structural

Cross-Section Properties

Area, moment of inertia, and section modulus for standard steel shapes and custom sections.


Ix Iy Zx ZyCustom ShapesComposite
Structural

Beam Deflection Calculator

Maximum deflection, bending moment, and shear force for simply supported and cantilever beams under distributed or point loads.


Simply SupportedCantileverDeflection Curve
Structural

Beam Reactions Calculator

Support reactions, max shear, and max bending moment with SFD/BMD diagrams for single-span beams.


Point & UDL LoadsSFD / BMDStatic Equilibrium
Structural

Column Buckling Calculator

Euler critical load, effective length, slenderness ratio, and critical stress for axially loaded columns.


Euler Critical Load4 End ConditionsSlenderness Ratio
Structural

Truss Analysis Calculator

Planar 2D determinate truss solver using the method of joints for member forces and support reactions.


Method of JointsMember ForcesDeterminacy Check
Structural

Punching Shear Calculator

Flat-slab two-way punching shear at a column with control perimeter and capacity check per ACI 318.


ACI 318Control PerimeterInterior/Edge/Corner
Structural

Base Plate Design Calculator

AISC 360 steel column base plate: bearing area, plate size, and required thickness for concentric columns.


AISC 360 LRFDBearing AreaPlate Thickness
Structural

Continuous Beam Calculator

Multi-span beam analysis via the Three-Moment Theorem for support moments, reactions, span moments, and a bending-moment diagram.


Three-Moment TheoremSupport ReactionsBending-Moment Diagram
Structural

Weld Group Calculator

Eccentrically loaded fillet welds by the elastic vector method, with shear flow, polar moment, and required fillet leg size.


Elastic Vector MethodPolar Moment JRequired Leg Size
Structural

Composite Beam Calculator

Steel-concrete composite beams: effective slab width, transformed section neutral axis and inertia, and plastic moment capacity.


Effective Slab WidthTransformed SectionPlastic Moment Mp
Structural

Shear Wall Design Calculator

In-plane shear design of a reinforced-concrete structural wall per ACI 318: concrete strength Vc, horizontal reinforcement Vs, capped nominal Vn, design phi*Vn versus Vu, utilization, and minimum/required reinforcement ratios.


ACI 318 Vc + VsVn Cap & φVnMin/Required ρt
Structural

Prestress Losses Calculator

Itemized prestress losses for prestressed and post-tensioned concrete: elastic shortening, creep, shrinkage, and steel relaxation, the total loss in MPa and percent, and the effective prestress fpe and effective force.


Elastic ShorteningCreep & ShrinkageEffective fpe & Pe
Structural

Fatigue Life Calculator

S-N detail-category fatigue life and Miner cumulative damage for a variable-amplitude load spectrum: allowable cycles per block, damage sum D, predicted spectrum repeats to failure, and the constant-amplitude fatigue limit.


S-N Detail CategoryMiner's Rule DCAFL & Life
Structural

Snow Load Calculator (ASCE 7-22)

ASCE 7-22 roof snow loads: flat-roof load pf = 0.7 Ce Ct Is pg, the low-slope minimum load, sloped balanced load with warm- and cold-roof slope factor curves, and the leeward drift surcharge against roof projections, with results in psf and kPa.


ASCE 7-22Drift Surchargepsf + kPa
Structural

Roof Pitch Calculator (Angle, Rafter & Area)

Roof pitch conversion between x/12, x/10, degrees and slope percent with flat-to-steep classification. Sizes common rafters from the horizontal run and pitch with an optional overhang, and converts plan footprint area to sloped roof area, roofing squares, and shingle bundles with waste.


Pitch ↔ Degrees ↔ %Rafter LengthSquares & Bundles
Structural

Deck Joist Span Calculator (IRC R507.6)

Maximum residential deck joist spans from 2021 IRC Table R507.6 (40 psf live + 10 psf dead, No. 2 grade): southern pine, Douglas fir-larch/hem-fir/SPF, and redwood/cedar 2x6 to 2x12 joists at 12, 16, or 24 inches on center, with the quarter-span cantilever check and a reverse lookup of every adequate size-and-spacing combination.


IRC R507.6 TableCantilever CheckReverse Lookup
Structural

Deck Beam Span & Footing Size Calculator (IRC R507.5)

Maximum multi-ply deck beam spans from 2021 IRC Table R507.5(1) for southern pine, Douglas fir-larch/hem-fir/SPF, and redwood/cedar build-ups of (2) 2x8 to (3) 2x12, with the joist span rounded up to the next table column. Sizes the post footing from the tributary load at 40 psf live + 10 psf dead against 1500-3000 psf soil bearing presets, and converts sonotube piers to concrete volume with 60-lb and 80-lb bag counts.


IRC R507.5 Beam TableFooting Ø for BearingSonotube Bags
Structural

Wall Framing Calculator (Studs, Plates & Headers)

Lumber takeoff for a conventionally framed stud wall per IRC 2021 R602 conventions: layout studs at 16 or 24 inches on center plus two extras per corner, one per T-intersection, and two kings, two jacks, and a cripple row per opening. Totals single or double top plate lineal footage, two-member header stock with 3-inch bearing each side, 4x8 sheathing sheets at 10% waste, and an advisory framing-nail weight — quantity counting only, not structural design.


Stud CountPlates & HeadersSheathing Sheets
Structural

Board Foot Calculator (Lumber BF & Cost)

Board feet and lumber cost from a multi-item list using the trade formula BF = nominal thickness x nominal width x length / 12 — nominal dimensions by convention, so a 2x6 counts as 2 x 6 despite dressing to 1.5 x 5.5 actual. Hardwood quarters thickness shortcut (4/4 = 1 in through 8/4 = 2 in), per-piece and per-line BF, running totals with a priced-BF subtotal, cost from optional dollars-per-board-foot prices on each line, and a display-only nominal-versus-actual dressed-size reference table.


BF per Piece & TotalQuarters (4/4-8/4)Cost Estimate
Structural

Deck Ledger Fastener Calculator (IRC R507.9)

Required 1/2-inch lag screw and thru-bolt on-center spacing from 2021 IRC Table R507.9.1.3(1) for a deck ledger fastened to a 2-inch nominal solid-sawn band joist, with the joist span rounded up to the governing column, staggered two-row fastener counts along the ledger run, Figure R507.9.1.3(2) placement reminders, and a reverse lookup of the largest joist span an existing fastener spacing supports.


IRC R507.9 TableFastener CountReverse Max Span
Structural

Header Span Calculator (IRC R602.7)

Maximum allowable spans and jack stud counts from 2021 IRC Table R602.7(1) for 2- and 3-ply built-up 2x6 to 2x12 headers in exterior bearing walls supporting a roof and ceiling at 30 psf ground snow, with building-width columns of 12, 24, and 36 ft, the NJ = 1 framing-anchor allowance, and a reverse lookup listing every tabulated header adequate for a required opening span with utilization.


IRC R602.7(1) TableJack Stud CountsReverse Lookup

Concrete & Foundations

11 Tools
Concrete & Foundations

Foundation Design

Shallow foundation design with bearing capacity, settlement analysis, punching shear, and flexural reinforcement per ACI 318, Eurocode 7, and AS 2159.


Terzaghi/Meyerhof/HansenSettlement AnalysisStructural Checks
Concrete & Foundations

Concrete Mix Design

Mix proportioning per ACI 211 with w/c ratio, aggregate sizing, and SCM replacement calculations.


ACI 211SCM ReplacementTrial Batch
Concrete & Foundations

Pile Foundation Design

Axial capacity and settlement analysis using alpha, beta, and SPT methods for driven and bored piles.


EC7/ASCEAlpha/Beta MethodSettlement
Concrete & Foundations

Rebar Scheduling & Detailing

Bar bending schedules and cutting length calculation with shape code library for reinforcement detailing.


BS 8666Shape CodesCutting Lengths
Concrete & Foundations

Concrete Crack Width Calculator

Flexural crack width wk of reinforced concrete with crack spacing and limit check per Eurocode 2.


Eurocode 2Crack Spacing0.3 mm Limit
Concrete & Foundations

Development Length Calculator

Rebar development length, Class A/B tension lap splices, and compression development per ACI 318-19.


ACI 318-19Lap SplicesModification Factors
Concrete & Foundations

Anchor Bolt Design Calculator

Single cast-in anchor tension and shear strengths with governing failure mode per ACI 318-19 Ch.17.


ACI 318-19Tension & ShearFailure Mode
Concrete & Foundations

Rebar Weight Calculator

Reinforcement steel mass from a bar schedule with totals by size in kilograms and tonnes.


Unit Mass/mTotals by SizeLap Allowance
Concrete & Foundations

Concrete Volume Calculator

Concrete quantity for slabs, footings, columns, and beams with bag count and cement/sand/aggregate breakdown.


m³ & yd³Waste AllowanceMix Breakdown
Concrete & Foundations

Brick, Block & Mortar Calculator

How many bricks or concrete blocks a wall needs from its dimensions and openings, using published rates for US modular, queen, king and UK standard brick and 8/6/4 in CMU or custom unit sizes. Includes premixed mortar bags, masonry sand quantity, and pallet counts with a waste allowance.


Brick & CMU PresetsMortar Bags & SandOpening Deductions
Concrete & Foundations

Concrete Steps Calculator (Volume & Riser Layout)

Solid poured-concrete steps takeoff from the total rise: equal-riser layout rounded up against the IRC R311.7.5 7.75-inch maximum riser with a 10-inch minimum tread check, stepped-mass volume of width x riser x tread x n(n+1)/2 plus an optional full-height top landing, a 10% waste allowance with cubic-foot and cubic-yard totals, 60-lb (0.45 ft³) and 80-lb (0.60 ft³) premixed bag counts, and formwork quantities as riser board lineal feet plus the two stepped side profiles in square feet.


Riser Layout + IRC CheckSolid-Step VolumeBags & Formwork

Geotechnical

12 Tools
Geotechnical

Retaining Wall Calculator

Retaining wall design with Rankine/Coulomb earth pressure, overturning/sliding/bearing stability checks, and reinforcement design for gravity and cantilever walls.


Rankine/CoulombStability ChecksReinforcement Design
Geotechnical

Soil Classification

Automatic USCS and AASHTO classification with Casagrande plasticity chart and grain-size analysis.


USCS/AASHTOAtterberg LimitsPlasticity Chart
Geotechnical

Bearing Capacity Calculator

Ultimate, gross, and net allowable bearing capacity of shallow footings (Terzaghi/Meyerhof).


Terzaghi/MeyerhofStrip/Square/CircularAllowable Pressure
Geotechnical

Consolidation Settlement Calculator

Primary consolidation settlement of clay for NC and OC soils using Terzaghi theory.


NC & OC Claye-log p′ CurveTerzaghi Theory
Geotechnical

Soil Compaction Calculator

Field dry density, relative compaction, air voids, and saturation against a Proctor maximum per ASTM D698.


Relative CompactionAir VoidsASTM D698
Geotechnical

Seepage Flow Calculator

Darcy law and flow-net seepage: hydraulic gradient, velocity, and discharge through soil masses.


Darcy's LawFlow NetSeepage Velocity
Geotechnical

Lateral Earth Pressure Calculator

Rankine active and passive earth pressure and thrust on retaining walls with surcharge and water table.


Rankine Ka/KpLateral ThrustSurcharge
Geotechnical

Slope Stability Calculator

Infinite-slope factor of safety for cohesionless, c-phi, and seepage cases.


Cohesionlessc-phi SoilSeepage Case
Geotechnical

Cantilever Sheet Pile Wall

Simplified cantilever sheet pile embedment depth in cohesionless soil using Rankine active and passive coefficients and a net-pressure moment balance about the toe: theoretical depth d0, design depth D = 1.2-1.3 d0, and the maximum bending moment.


Rankine Ka & KpEmbedment DepthMax Bending Moment
Geotechnical

Soil Liquefaction Triggering

Simplified Seed-Idriss / NCEER liquefaction-triggering analysis: cyclic stress ratio CSR, cyclic resistance ratio CRR7.5 from corrected SPT (N1)60, magnitude scaling factor and the factor of safety against liquefaction with a verdict.


CSR vs CRRNCEER 1997FS & Verdict
Geotechnical

Mononobe-Okabe Seismic Earth Pressure

Pseudo-static seismic active earth pressure on a retaining wall by the Mononobe-Okabe method: seismic inertia angle, coefficient KAE, static KA, total seismic thrust PAE, the Seed-Whitman dynamic increment and the point of application.


Seismic KAEDynamic IncrementPoint of Application
Geotechnical

Retaining Wall Block Calculator (SRW ≤ 4 ft)

Segmental retaining wall block takeoff for simple gravity walls up to 4 ft of exposed height per NCMA-style practice: courses and blocks per course from standard 12x4x9, large 18x6x12, or custom block sizes with the buried base course included (the greater of 6 in or 10% of the exposed height), optional cap units one per block width of length, compacted leveling-pad gravel 6 in deep by the block depth plus 12 in wide with a 1.15 loose-to-compacted factor, and the 12-in clean drainage-rock column over the exposed height — taller, surcharged, or sloped-backfill walls are referred to the engineered retaining-wall calculator.


Blocks & CoursesBase & Drainage Rock4-ft Gravity Limit

Hydraulics & Water

18 Tools
Hydraulics & Water

Plumbing & Drainage Sizing

Pipe sizing via fixture unit method with flow rate, velocity, and self-cleansing velocity checks.


IPC/EN 12056Fixture UnitsSelf-Cleansing
Hydraulics & Water

Pump Sizing Calculator

System curve generation, duty point selection, and NPSH verification with affinity law calculations.


System CurveNPSH CheckDuty Point
Hydraulics & Water

Stormwater Drainage Calculator

Rational method pipe and channel sizing with IDF curves and runoff coefficient analysis.


Rational MethodIDF CurvesPipe Sizing
Hydraulics & Water

Rainwater Harvesting Calculator

Roof catchment yield (V = A·R·C·eff) and tank sizing with a month-by-month water balance.


BS 8515Yield & Tank SizeMonthly Balance
Hydraulics & Water

Detention Basin Calculator

Stormwater detention storage via the Modified Rational Method with critical-duration search.


Modified RationalIDF CurveCritical Duration
Hydraulics & Water

Water Hammer Calculator

Joukowsky pressure surge, wave celerity and critical period 2L/a for rapid and gradual valve closure.


JoukowskyWave CelerityRapid vs Gradual
Hydraulics & Water

Open-Channel Flow Calculator

Manning's equation uniform flow for rectangular, trapezoidal, triangular, and circular channels.


Manning's EquationHydraulic RadiusFroude Number
Hydraulics & Water

Weir & Notch Flow Calculator

Discharge for rectangular, V-notch, and Cipolletti thin-plate weirs per ISO 1438.


RectangularV-NotchCipolletti
Hydraulics & Water

Culvert Sizing Calculator

Inlet and outlet control capacity for circular and box culverts per FHWA HDS-5.


Inlet ControlOutlet ControlFHWA HDS-5
Hydraulics & Water

Hydraulic Jump Calculator

Hydraulic jump in a rectangular channel: upstream Froude number, sequent (conjugate) depth, downstream velocity and Froude number, specific-energy loss, percentage dissipated, jump length and the USBR jump classification.


Sequent DepthEnergy LossJump Type
Hydraulics & Water

Evapotranspiration (ET0) Calculator

Reference crop evapotranspiration by the Hargreaves equation (FAO-56 alternative): extraterrestrial radiation from latitude and day-of-year, crop ET via the crop coefficient Kc, and the net irrigation requirement with monthly totals.


Hargreaves ET0Crop ET (Kc)Irrigation Need
Hydraulics & Water

Gravity Sewer Design Calculator

Circular gravity sewer design with Manning's equation: full-flow capacity and velocity, proportional depth d/D at the design flow, partial-flow velocity, capacity utilization and a self-cleansing velocity check.


Full-Flow Capacityd/D Partial FlowSelf-Cleansing
Hydraulics & Water

Rational Method Peak Runoff Calculator

Peak stormwater runoff by the rational method Q = CiA with an area-weighted composite runoff coefficient, time of concentration by the Kirpich and FAA formulas, and SCS/NRCS Curve Number runoff depth and volume, with peak flow in m³/s, cfs and L/s.


Q = CiAKirpich & FAA tcSCS Curve Number
Hydraulics & Water

Gutter & Downspout Sizing Calculator

K-style gutter sizing and downspout counts from representative SMACNA-style practice capacities: roof plan area adjusted by pitch factors from 1.0 (flat to 3/12) to 1.3 (12/12), normalized to the 1 in/hr capacity basis with the local 5-minute 10-year rainfall intensity, 5-in (2,500 ft²) and 6-in (3,840 ft²) K-style adequacy with utilization and a smallest-adequate recommendation, and per-type counts of 2x3, 3x4, and 4-in round downspouts from both drainage capacity and the 40-ft advisory spacing.


Pitch-Adjusted Area5" vs 6" K-StyleDownspout Count
Hydraulics & Water

Septic Drain Field Size Calculator

Septic drain field (leach field) sizing from representative published state tables with the local health department always governing: design flow at 150 gpd per bedroom (Maryland COMAR 26.04.02.05 residential minimum; NY allows 110 gpd/bedroom with post-1994 fixtures), application rate from the NY Appendix 75-A Table 4B percolation bands transcribed cell-for-cell (1.20 gal/ft²/day at 1–5 min/in stepping down to 0.45 at 46–60 min/in), required trench-bottom area as flow ÷ rate, total absorption trench length at a 2- or 3-ft width split into equal laterals of at most 100 ft, minimum septic tank guidance from NY Table 3 (1,000 gal through 3 bedrooms, 1,250 at 4, 1,500 at 5), unsuitable-soil guidance toward mound and alternative systems for perc rates faster than 1 or slower than 60 min/in, and a required-area chart across every perc band at the chosen bedroom count.


Flow by BedroomsPerc → Application RateTrench Layout
Hydraulics & Water

Water Softener Sizing Calculator (Grains)

Softener grain-capacity sizing from representative plumbing-trade practice: household demand at 75 gal per person per day, hardness in grains per gallon or ppm converted at 17.1 ppm/gpg, dissolved clear-water iron compensated at +5 gpg per 1 ppm (published guides commonly cite 4–5; iron above ~0.3 ppm often wants dedicated treatment ahead of the softener), the weekly grain load on a one-regeneration-per-week basis matched to the smallest fitting standard capacity from 24,000 to 80,000 grains, a utilization chart across all six sizes against the 100% line, and twin-tank or frequent-regeneration guidance when even the largest single-tank size is too small — all framed as estimates to confirm against the manufacturer’s sizing chart.


Grains per Weekppm ↔ gpg + IronStandard Sizes
Hydraulics & Water

French Drain Calculator (Gravel, Fabric & Pipe)

French drain material estimator from representative drainage-trade practice: trench volume from width (6/9/12-in presets or 6–24-in custom), depth, and run length with the standard 4-inch perforated pipe displacement subtracted so stone the pipe already fills is not bought, washed drainage gravel in cubic feet, cubic yards, and tons at 1.4 tons per cubic yard (link to gravel-aggregate for other materials), non-woven filter fabric from the burrito-wrap girth — twice the width plus twice the depth plus a 12-inch lap, covering walls, bottom, and a full top pass — counted in 3 × 100 ft rolls at 90% overlap-effective coverage, perforated pipe with a 5% fittings allowance rounded up to 10-ft sticks, a slope check against the 1% practice minimum (0.12 in/ft, with the 0.5% smooth-wall nuance in prose) or the required fall when no drop is entered, and a gravel-tons-by-width comparison chart.


Gravel & FabricPipe & Fittings1% Slope Check
Hydraulics & Water

Sprinkler Zone Calculator (GPM & Zones)

Irrigation zone calculator from representative trade practice: available flow measured with a bucket-test helper (gallons ÷ seconds × 60, with a use-this button) or typical meter-size presets (12/16/25 GPM for 5/8-, 3/4-, and 1-inch meters, clearly labeled typical — measure yours), a 90% design margin on the measured supply so a hot-afternoon pressure dip does not starve the farthest heads, sprinkler-head rows by type (label, GPM each from the nozzle chart, count) summed into total demand, the zone count as total demand divided by usable flow rounded up per the Hunter design-handbook method, an advisory equal demand split, a per-head-type maximum-heads-per-zone fit table (epsilon-guarded floor), and a demand-per-zone bar chart against the budget line.


Bucket-Test GPMDemand vs SupplyZone Count

Transportation & Surveying

10 Tools
Transportation & Surveying

Flexible Pavement Design Calculator

AASHTO 1993 structural number from ESALs, reliability, serviceability, and subgrade MR.


AASHTO 1993Structural NumberLayer Schedule
Transportation & Surveying

Vertical Curve Calculator

Parabolic crest and sag curves: A, K, BVC/EVC, high/low point, and sight-distance length per AASHTO.


Crest & SagK ValueHigh/Low Point
Transportation & Surveying

Stopping Sight Distance Calculator

AASHTO reaction, braking, and total stopping sight distance with grade correction (US & SI).


AASHTO SSDReaction & BrakingGrade Correction
Transportation & Surveying

Horizontal Curve Calculator

Simple highway circular curve: minimum radius from design speed, plus tangent, curve length, external, middle ordinate, long chord, degree of curve, and PC/PT stationing.


Minimum RadiusT, L, E, M, LCPC/PT Stationing
Transportation & Surveying

Rigid Pavement Design Calculator

AASHTO 1993 PCC slab thickness from ESALs, reliability, concrete strength, subgrade k, load transfer J, and drainage Cd.


AASHTO 1993 RigidSlab ThicknessLoad Transfer J
Transportation & Surveying

Traffic Flow Capacity Calculator

Greenshields uninterrupted flow: capacity q_max = vf·kj/4, optimum speed and density, and free-flow vs congested branches with a flow-density curve.


Greenshields ModelCapacity q_maxFree vs Congested
Transportation & Surveying

Area by Coordinates Calculator

Area of a closed traverse or land parcel from vertex coordinates using the Shoelace formula, plus perimeter, centroid, and winding direction.


Shoelace FormulaPolygon CentroidWinding Direction
Transportation & Surveying

Traverse Closure & Bowditch Adjustment

Latitudes, departures, linear misclosure, and relative precision of a closed traverse, balanced with the Bowditch compass-rule adjustment.


Latitudes & DeparturesLinear MisclosureBowditch Adjustment
Transportation & Surveying

Bearing & Distance (COGO) Calculator

Inverse and forward COGO computations: distance and azimuth between coordinates, and a new point from bearing and distance.


Inverse ProblemForward ProblemAzimuth & DMS
Transportation & Surveying

Asphalt Tonnage Calculator

Tons of hot-mix asphalt from up to five paved areas, compacted thickness, and mix density. Includes HMA, binder, and open-graded density presets, waste factor, 25-ton truckloads, and an optional cost estimate.


Short Tons & TonnesDensity PresetsTruckloads & Cost

Mechanical & Machine Design

10 Tools
Mechanical & Machine Design

Pressure Vessel Thickness Calculator

Wall thickness for cylindrical and spherical shells under internal pressure per ASME BPVC Section VIII Div 1, with corrosion allowance and MAWP.


Hoop & Longitudinal StressCorrosion AllowanceMAWP
Mechanical & Machine Design

Bolt Torque & Preload Calculator

Tightening torque and preload via T = K·F·d with ISO metric thread geometry and ISO 898-1 property classes.


Tensile Stress AreaTarget PreloadRequired Torque
Mechanical & Machine Design

Pipe Thermal Expansion Calculator

Linear thermal growth, restrained thermal stress, anchor force, and expansion-loop leg length for process and power piping.


Free ExpansionRestrained StressExpansion Loop
Mechanical & Machine Design

Orifice Flow Meter Calculator

Volumetric and mass flow through a thin-plate orifice per ISO 5167, with diameter ratio, velocity-of-approach factor, pipe and throat velocities, and throat Reynolds number.


ISO 5167Velocity-of-ApproachMass Flow
Mechanical & Machine Design

Tank Volume Calculator

Partial-fill liquid volume for vertical, horizontal, and rectangular tanks, with total capacity, percent full, and ullage in cubic metres, litres, and US gallons.


Horizontal SegmentPercent FullLitres & Gallons
Mechanical & Machine Design

Reynolds Number & Friction Factor

Pipe-flow Reynolds number, laminar/transitional/turbulent regime, and Darcy friction factor via 64/Re or Colebrook-White and Swamee-Jain, with relative roughness and a Moody curve.


Re = ρvD/μColebrook-WhiteMoody Curve
Mechanical & Machine Design

Shaft Design Calculator

Required solid circular shaft diameter under combined bending and torsion by the maximum-shear (Tresca) or distortion-energy (von Mises) theory, with fatigue stress-concentration factors and actual bending, shear and von Mises stresses.


Tresca & von MisesKb / Kt FactorsActual Stresses & FS
Mechanical & Machine Design

Helical Spring Calculator

Helical compression spring design: spring index, Wahl correction factor, spring rate k = G·d⁴/(8·D³·Na), deflection, Wahl-corrected shear stress and solid length, with manufacturability warnings on spring index.


Spring Rate kWahl FactorShear Stress
Mechanical & Machine Design

Bearing Life Calculator

Rolling-element bearing fatigue life per ISO 281: equivalent dynamic load, basic rating life L10 = (C/P)^p in million revolutions and hours for ball and roller bearings, plus reliability-adjusted life.


L10 = (C/P)^pMrev & HoursReliability a1
Mechanical & Machine Design

Vibration Isolation Calculator

Machine vibration isolator selection: natural frequency from static deflection or spring stiffness and mass, frequency ratio, damped transmissibility, and isolation efficiency, with a reverse mode giving the required static deflection for a target isolation percentage.


TransmissibilityNatural FrequencyIsolation %

Marine & Coastal

3 Tools

Building Physics & Energy

11 Tools
Building Physics & Energy

Energy Efficiency Calculator

Building thermal performance, energy consumption analysis, and cost savings projections.


Heat Loss AnalysisEnergy ModelingROI Projections
Building Physics & Energy

Thermal Movement Calculator

Thermal expansion, joint widths, and sealant selection for facade elements.


80+ MaterialsJoint DesignSealant Selection
Building Physics & Energy

Condensation Risk Calculator

Interstitial condensation analysis using the Glaser method with vapour pressure profiles.


122 MaterialsGlaser MethodMonthly Analysis
Building Physics & Energy

Thermal Bridge Calculator

Thermal junction analysis with psi-values, temperature factors, and standards compliance.


59 Junction CatalogPsi-Value AnalysisCompliance Check
Building Physics & Energy

Heat Loss & Gain Calculator

Room-by-room heating and cooling load analysis with fabric loss, ventilation, solar gains, and internal gains.


EN 12831ASHRAE MJ8Multi-Room
Building Physics & Energy

U-Value Calculator

Assembly thermal transmittance with layer-by-layer resistance calculation and thermal bridging corrections.


ISO 6946200+ MaterialsBridging Corrections
Building Physics & Energy

Overheating Risk Assessment

Summer comfort analysis with hourly simulation per CIBSE TM59/TM52, EN 15251, and ASHRAE 55.


CIBSE TM59Adaptive ComfortHourly Simulation
Building Physics & Energy

Moisture & Mould Risk Calculator

Surface temperature factor and mould growth prediction for wall junctions and assemblies.


BS 5250fRsi FactorMould Growth
Building Physics & Energy

Psychrometric Calculator

Moist-air properties: humidity ratio, enthalpy, dew point, and wet-bulb at any atmospheric pressure.


Humidity RatioEnthalpyDew & Wet-Bulb
Building Physics & Energy

Degree Days & Energy Calculator

Heating and cooling degree-days with a simplified building energy estimate per ASHRAE & CIBSE.


HDD & CDDEnergy EstimateDaily/Monthly
Building Physics & Energy

Insulation R-Value Calculator (IECC Climate Zones)

Prescriptive minimum insulation R-values from IECC 2021 Table R402.1.3 for ceilings, wood-frame walls, floors, basement walls, and crawl space walls across climate zones 1-8, with the full compound code option text (cavity and continuous-insulation alternatives), a fiberglass batt purchase plan with layers and bag counts, and blown-in fiberglass or cellulose depth in whole inches.


IECC 2021 MinimumsBatt Bag CountsBlown-In Depth

HVAC & Comfort

17 Tools
HVAC & Comfort

Daylight / Solar Gain

Solar heat gain, visible light transmittance, daylight factor, and shading analysis for glazing systems.


20 Glazing TypesShading AnalysisCode Compliance
HVAC & Comfort

Pipe & Duct Sizing

Pipe and duct sizing calculator using Darcy-Weisbach equation with pressure drop, fitting losses, and material databases.


Darcy-WeisbachPipe & Duct SizingFitting Losses
HVAC & Comfort

HVAC Load Calculator

Heating and cooling load sizing with sensible/latent analysis, psychrometrics, and equipment tonnage.


ASHRAE MJ8Latent LoadsEquipment Sizing
HVAC & Comfort

Ventilation Rate Calculator

Required airflow calculation per ASHRAE 62.1, EN 16798, and CIBSE Guide B with demand-controlled ventilation.


ASHRAE 62.1EN 16798Demand Control
HVAC & Comfort

Heat Exchanger LMTD Calculator

LMTD and effectiveness-NTU sizing/rating for counter-flow and parallel-flow heat exchangers.


LMTD MethodEffectiveness-NTURequired Area
HVAC & Comfort

Fan & Pump Affinity Laws Calculator

Affinity laws for new flow, pressure, and power from speed or impeller diameter changes.


Speed ChangeDiameter TrimPower Cubed
HVAC & Comfort

Cooling Tower Calculator

Range, approach, heat rejection, evaporation, blowdown, and makeup water with thermal efficiency.


Range & ApproachHeat RejectionMakeup Water
HVAC & Comfort

Heat Pump COP Calculator

Carnot and actual COP, EER, running cost, and savings versus electric resistance heating.


Carnot & Actual COPEERCost Savings
HVAC & Comfort

Expansion Tank Sizing Calculator

Hydronic expansion tank sizing by the ASHRAE closed-loop method: water expansion volume, acceptance factor, and required tank volume.


Expansion VolumeAcceptance FactorTank Volume
HVAC & Comfort

Chilled & Hot Water Flow Calculator

Hydronic chilled-water and hot-water flow rate from a cooling or heating load via Q = m·cp·ΔT: mass flow, L/s, m³/h and US GPM, plus pipe velocity and a suggested pipe size for a target velocity.


Q = m·cp·ΔTL/s · m³/h · GPMPipe Velocity & Size
HVAC & Comfort

Air Mixing Calculator

Adiabatic mixing of two moist-air streams such as outdoor and return air: mass-weighted mixed dry-bulb, humidity ratio, enthalpy, relative humidity and dew point on a dry-air basis.


Mass-Weighted MixW, h & RHOutdoor + Return Air
HVAC & Comfort

Cooling Coil Load Calculator

Cooling coil total load split into sensible and latent components from the entering and leaving air conditions using ASHRAE psychrometrics, with dry-air mass flow, cooling in kW and refrigeration tons, the sensible heat ratio (SHR), and the condensate removal rate.


Sensible / LatentSHRCondensate Rate
HVAC & Comfort

Geothermal Borehole (GSHP) Sizing Calculator

Ground-source heat pump vertical borehole sizing: ground load from the building heating or cooling load and COP, total bore length from the W/m heat-transfer rate, and the number and depth of boreholes per ASHRAE / IGSHPA rule-of-thumb design.


Ground LoadBore LengthBorehole Count
HVAC & Comfort

Gas Pipe Sizing Calculator (NFPA 54)

Low-pressure natural gas pipe sizing by the NFPA 54 / IFGC longest-length method: BTU/hr load (or a per-appliance list) to CFH demand, Schedule 40 capacities from Table 402.4(2) at the rounded-up run length, the smallest adequate size with utilization and next size up, and a Spitzglass formula cross-check.


NFPA 54 TableLongest-LengthCFH Demand
HVAC & Comfort

Attic Ventilation Calculator (IRC 1/150 & 1/300 Rule)

Required attic net free ventilating area per IRC 2021 R806.2: 1/150 of the attic floor area, or 1/300 when both exception conditions are met (Climate Zone 6-8 ceiling vapor retarder, 40-50% of the NFA in upper-portion ventilators), split 50/50 into upper exhaust and eave intake targets. Converts each half into ridge vent lineal feet, 8x16 soffit vents, continuous soffit strip, box vents, gable louvers, or turbines from representative NFA ratings, and a check mode grades an existing vent mix with pass/fail, deficit, and an intake/exhaust balance warning.


1/150 & 1/300 RulesIntake/Exhaust SplitVent Counts by Type
HVAC & Comfort

Water Heater Sizing Calculator (FHR & Tankless GPM)

Water heater sizing both ways the DOE Energy Saver method recommends: tank mode fills in the DOE Worksheet for Estimating Peak Hour Demand/First Hour Rating with the published averages — shower 20 gal per use, shaving 2, hand dishwashing or food prep 3, automatic dishwasher 7, clothes washer 25 (top-loader) or 15 (H-axis) — and matches the total to a storage or heat-pump model with a first hour rating at or just above the demand (size by the EnergyGuide FHR, never by tank volume); tankless mode sums representative simultaneous fixture flows (shower 2.0 gpm, kitchen sink 1.5, lavatory 1.0, clothes washer 2.0, dishwasher 1.5) and computes the required temperature rise from groundwater (regional presets 40-70 °F) to the fixed 120 °F delivery, compared against a typical gas unit of about 5 gpm — and an electric unit of about 2 gpm — at a 70 °F rise.


Peak-Hour FHRTankless GPM & RiseDOE Worksheet
HVAC & Comfort

Whole House Fan Sizing Calculator (CFM & Attic NFA)

Whole house fan sizing from published DOE and manufacturer practice: target airflow at 2, 2.5, or 3 CFM per square foot of living area (the QuietCool good/better/best sizing ladder, inside the PNNL Building America 1.5–3 CFM/ft² band), an air-changes-per-hour cross-check from house volume against the 12–23 ACH effective range with a tall-ceiling size-up flag, the attic exhaust net free area the fan needs at 1 ft² per 750 CFM in ft² and in² (doubled to gross area for screened or louvered vents, with a link to attic-ventilation for vent selection), the open-window guideline of 4 ft² per 1,000 CFM, and a good/better/best CFM comparison chart — windows-open night-flush ventilation cooling, not a substitute for load-based HVAC design.


CFM by Floor AreaACH Cross-CheckAttic NFA Required

Electrical & MEP

19 Tools
Electrical & MEP

Electrical Load Calculator

NEC Article 220 demand factor calculations with service sizing, cable selection, and panel schedule generation.


NEC Article 220Cable SizingPanel Schedule
Electrical & MEP

Lighting Design Calculator

Luminaire layout using zonal cavity method with lux levels, uniformity ratio, and power density.


Zonal Cavity12 LuminairesGrid Layout
Electrical & MEP

Solar PV Yield Calculator

Panel array sizing and annual energy yield estimation with tilt and azimuth optimisation.


IEC 61853Yield ForecastTilt Optimizer
Electrical & MEP

Cable Tray & Conduit Sizing

Fill ratio and derating calculations for cable trays, conduits, and electrical raceways.


NEC Art. 392Fill RatioDerating
Electrical & MEP

Voltage Drop Calculator

Single and three-phase conductor voltage drop with NEC 3%/5% and IEC 60364 compliance checks.


1Φ & 3ΦCu & AlNEC / IEC Limits
Electrical & MEP

Fault Current Calculator

Available short-circuit current at a transformer and downstream points via the point-to-point method.


Transformer FaultPoint-to-PointMotor Contribution
Electrical & MEP

Transformer Sizing Calculator

Required kVA, next standard rating, and full-load currents for single and three-phase transformers.


Required kVAStandard RatingFull-Load Current
Electrical & MEP

Power Factor Correction Calculator

Capacitor kVAR sizing, current and loss reduction, and demand-charge savings for PF correction.


Capacitor kVARLoss ReductionSavings
Electrical & MEP

Grounding Resistance Calculator

Earthing resistance of driven rods, parallel rods, and ground grids against the 25-ohm NEC target.


Dwight / IEEE 142Parallel RodsGround Grid
Electrical & MEP

Generator Sizing Calculator

Standby/prime genset kW and kVA from running load and motor starting with derating and spare margin.


Running & StartingDeratingStandard Size
Electrical & MEP

Arc-Flash Calculator

IEEE 1584 arcing current, incident energy, arc-flash boundary, and NFPA 70E PPE category.


IEEE 1584Incident EnergyPPE Category
Electrical & MEP

Motor Starting & Voltage Dip Calculator

Three-phase motor full-load and locked-rotor current, bus voltage dip, and reduced-voltage starting method comparison.


Full-Load CurrentLocked-Rotor kVAVoltage Dip
Electrical & MEP

Lightning Protection (Rolling Sphere)

Rolling-sphere method of IEC 62305-3 for sphere radius, protected radius and area, mesh size, and protection angle.


Rolling-Sphere RadiusProtected AreaMesh & Angle
Electrical & MEP

EV Charging Load Calculator

Electric-vehicle charging (EVSE) load sizing per NEC Article 625: per-charger continuous load at 125%, single- and three-phase circuit current, total connected demand in amps and kVA, and an energy-management diversity factor for the recommended feeder/service ampacity.


125% ContinuousConnected DemandDiversity Factor
Electrical & MEP

Harmonic Distortion & K-Factor Calculator

Total harmonic distortion (THD), true RMS and transformer K-factor from a measured harmonic spectrum per IEEE 519 and IEEE C57.110, with the recommended K-rated transformer and distortion-limit guidance.


THD %K-FactorIEEE 519
Electrical & MEP

Conductor Ampacity Calculator (NEC 310.16)

NEC Table 310.16 wire sizing for copper and aluminum conductors: ampacity by insulation temperature rating with ambient-temperature correction and conductor-bundling adjustment, continuous-load 125% sizing, and termination temperature limit checks.


NEC 310.16Derating FactorsCu & Al
Electrical & MEP

Conduit Bending Calculator (Offset, Saddle, Stub-Up)

EMT hand-bender layout for the three everyday bends: two-bend offsets with the exact 1/sin(angle) multiplier and shrink, 3-point saddle center and outer marks, and 90 degree stub-ups using the bender take-up deduct per trade size, with mark positions from the obstruction and a bend-spacing check.


Offset MultiplierSaddle MarksStub-Up Take-Up
Electrical & MEP

Box Fill Calculator (NEC 314.16)

Minimum outlet, device, and junction box volume per NEC 314.16(B): Table 314.16(B) allowances for conductors by AWG size, internal clamps, support fittings, device yokes at two allowances each, and equipment grounding conductors, with every standard box that fits listed with its utilization percentage.


NEC 314.16(B)Per-Rule BreakdownBox Suggestions
Electrical & MEP

Outlet Spacing Calculator (NEC 210.52)

Minimum dwelling-unit receptacle counts per NEC 210.52, verified against the published 2023 code text (every encoded value is identical in the 2020 edition): wall spaces entered in feet under the 210.52(A) 6-ft rule — no point along the floor line more than 6 ft from a receptacle, so receptacles at most 12 ft apart, with any space 2 ft or wider counting and doorways, fireplaces, and fixed cabinets breaking the wall line — and wall countertop segments entered in inches under the 210.52(C) 24-in rule with the 12-in minimum width, each list giving per-segment minimums plus wall, countertop, and grand totals, documented as code minimums that real layouts exceed, with the 2023 island/peninsula change (receptacles now optional with a future-provision requirement) and GFCI/AFCI protection covered in prose.


NEC 210.52 WallsCountertop RulePer-Segment Counts

Renewable Energy

4 Tools

Acoustics

2 Tools

Fire & Life Safety

6 Tools
Fire & Life Safety

Fire Resistance Rating

Fire resistance rating calculator with REI classification for concrete, steel, and timber structural members.


REI ClassificationConcrete/Steel/TimberISO 834 + ASTM E119
Fire & Life Safety

Fire Sprinkler Design

Hydraulic calculation with head layout, pipe sizing, and water supply analysis for sprinkler systems.


NFPA 13Hydraulic CalcHead Layout
Fire & Life Safety

Occupant Load & Egress Calculator

Occupant load, required egress width, and number of exits per IBC 1004, 1005, 1006.


IBC 1004Egress WidthNumber of Exits
Fire & Life Safety

Needed Fire Flow Calculator

Needed fire flow (NFF) by the ISO / AWWA area method NFF = 18 x C x sqrt(A): construction-class coefficient, effective floor area, required flow in gpm and L/min, the required flow duration and the total water supply for hydrant and storage sizing.


18 C sqrt(A)Flow DurationWater Supply
Fire & Life Safety

Egress Window Calculator (IRC R310)

Emergency escape and rescue opening sizing and checking per IRC 2021 R310.2 (source-verified): size-it mode returns the net clear width or height needed to reach the 5.7 sq ft net clear opening — 5.0 sq ft for grade floor or below grade openings per the R310.2.1 exception — floored at the 24-in height and 20-in width minimums with the governing rule named, check-it mode grades an as-built opening rule by rule (area, width, height, and the R310.2.2 44-in maximum sill) with the margin and IRC section on each badge, and a window well card checks the R310.2.3 minimums (9 sq ft horizontal area with projection and width each at least 36 in) and flags the permanently affixed ladder or steps R310.2.3.1 requires for wells deeper than 44 in.


5.7 sq ft Net ClearMin 24x20 & 44-in SillWindow Well Check
Fire & Life Safety

Smoke & CO Detector Calculator (IRC R314/R315)

Minimum smoke and carbon monoxide alarm counts for a dwelling unit per the IRC 2021 published text (source-verified): smoke alarms per R314.3 — one in each sleeping room, one outside each separate sleeping area in the immediate vicinity of the bedrooms, and one on each additional story including basements and habitable attics but not crawl spaces or uninhabitable attics — and CO alarms per R315.2.1/R315.3 where the dwelling has a fuel-fired appliance or an attached garage with a communicating opening: one outside each sleeping area plus one inside any bedroom with a fuel-burning appliance in the room or its attached bathroom, every count itemized as per-rule breakdown lines with section references, documented as conservative planning minimums with the placement restrictions (3 ft from tub/shower bathroom doors, 6–20 ft from cooking appliances by sensor type), interconnection (R314.4/R315.5), and hardwired-plus-battery power rules (R314.6/R315.6) covered in prose.


IRC R314 CountsCO per R315Per-Rule Breakdown

Site & Sustainability

22 Tools
Site & Sustainability

Window Fabrication Calculator

Cutting lists and fabrication drawings for aluminum windows with optimized material usage.


Cutting OptimizationProfile DatabaseTechnical Drawings
Site & Sustainability

Embodied Carbon Calculator

Whole-life carbon emissions with lifecycle assessment across stages A1-D per EN 15978.


201 MaterialsLifecycle Stages A-DBenchmarks
Site & Sustainability

Temporary Works Design

Scaffolding, formwork, and shoring load checks with stability analysis for construction.


BS 5975ScaffoldingFormwork
Site & Sustainability

Earthwork Cut & Fill Calculator

Cut and fill volumes by average-end-area and prismoidal methods with shrinkage and haul balance.


Average-End-AreaPrismoidalHaul Balance
Site & Sustainability

Life-Cycle Cost Calculator

LCCA with NPV, simple and discounted payback, and savings-to-investment ratio for two options.


NPVPaybackSIR
Site & Sustainability

Stair Calculator (Rise, Run & Code Check)

Straight-flight stair design from the floor-to-floor rise: number of risers, actual riser height, treads, total run, stair angle and stringer length, checked against IBC, IRC, OSHA or custom riser and tread limits and the Blondel 2R + T comfort rules.


IBC / IRC / OSHABlondel 2R + TStringer Length
Site & Sustainability

Rigging Sling Load Calculator

Lifting sling tension per leg from load weight, leg count and sling angle from horizontal, with the angle factor, required WLL per leg for vertical, choker and basket hitches, horizontal compression on the load, and OSHA / ASME B30.9 sling-angle warnings.


Tension per LegAngle FactorRequired WLL
Site & Sustainability

Gravel & Aggregate Calculator

Cubic yards, cubic metres, and tonnage of crushed stone, pea gravel, sand, crusher run, riprap, or topsoil from rectangular, circular, or direct areas. Compaction and waste allowances with bag counts and 10 yd³ truckloads.


6 Material PresetsRect / Circle AreasBags & Truckloads
Site & Sustainability

ADA Ramp Slope Calculator

Accessible ramp design per the 2010 ADA Standards and ICC A117.1: required run at 1:12, 1:16 or 1:20 (plus the 1:10 and 1:8 existing-site exceptions), intermediate landings from the 30 in rise limit, total footprint, handrail flag, and a check mode that grades an existing rise and run with pass/fail margins.


1:12 / 1:16 / 1:20Landings per 405.6Pass/Fail Margins
Site & Sustainability

Decking Board & Fastener Calculator

Deck board and fastener quantities from the footprint: rows from the board width plus gap (5.5 in and 3.5 in presets or custom), lineal footage with a 10% straight or 15% diagonal waste allowance, boards to buy at 8 to 20 ft stock lengths, and face screws at two per joist crossing or hidden clips at one per crossing plus a starter per row, with 100/350/1750-count box suggestions.


Boards & Lineal FtScrews or ClipsDiagonal Waste
Site & Sustainability

Baluster Spacing Calculator (IRC 4-Inch Rule)

Guard baluster layout under the IRC R312.1.3 4-inch-sphere rule: the minimum number of balusters for a clear opening between posts, the perfectly even clear gap with a pass/fail badge, and center-line layout marks measured from the post face, plus an as-built check mode that verifies an existing baluster count and reports the margin to the 4-inch limit or a custom maximum such as the 4-3/8-inch allowance for guards on the open sides of stairs.


4-in Sphere RuleEven-Spacing LayoutAs-Built Check
Site & Sustainability

Drywall Calculator (Sheets, Mud, Tape & Screws)

Drywall quantity takeoff for a rectangular room (with or without the ceiling) or a list of wall segments, subtracting door and window openings. Counts 4x8, 4x10, or 4x12 sheets at 10% standard or 15% complex waste and converts representative trade coverage rates into joint compound pounds and 4.5-gallon buckets, tape lineal feet and 500-ft rolls, screws and 1000-count boxes, plus 8-ft corner bead sticks from the entered outside-corner footage.


Sheets with WasteMud, Tape, Screws4x8 / 4x10 / 4x12
Site & Sustainability

Tile Calculator (Tiles, Thinset & Grout)

Tile quantity takeoff for a floor or wall entered directly in square feet or as length by width: tiles and boxes from the effective footprint of each tile including its grout joint, with pattern waste at 10% straight or offset, 15% diagonal, and 20% herringbone. Counts 50-lb thinset bags from representative 1/4, 3/8, or 1/2 inch square-notch trowel coverage and grout pounds from the industry-standard joint-geometry formula, rounded into 10-lb and 25-lb bags.


Pattern Waste %Thinset by TrowelGrout by Geometry
Site & Sustainability

Fence Calculator (Posts, Rails, Pickets & Concrete)

Wood fence material takeoff from the run length: posts and sections at 6 or 8 ft on center, rails per section by style (3 privacy, 2 picket, 2-3 post-and-rail), pickets from the picket width and gap, post length to buy rounded to even-foot stock from the trade 1/3-height bury rule (2 ft minimum), post holes at three times the post width over a 4-inch gravel base, and concrete per hole and total with 60-lb and 80-lb premix bag counts plus one extra post and hardware set per gate.


Posts & SectionsPickets & RailsConcrete per Post
Site & Sustainability

Paver Patio Calculator (Pavers, Base & Sand)

Interlocking concrete paver takeoff for patios, walkways, and driveway aprons: pavers to buy from 4x8, 6x6, 6x9, 12x12, or custom face sizes with pattern waste (5% running or stack bond, 10% herringbone, 15% circular), compacted aggregate base at 4-in pedestrian or 8-in vehicular depth with a 1.15 loose-to-compacted factor, bedding sand at the fixed 1-inch ICPI screed, polymeric jointing sand bags at representative 80 ft² coverage, and 8-ft edge restraint sticks along the open perimeter.


Paver Counts by PatternBase & Bedding SandPolymeric Sand Bags
Site & Sustainability

Siding Calculator (Squares, Planks & Trim)

Horizontal lap-siding takeoff from up to 20 wall elevations with door and window openings subtracted: siding squares and course-equivalent lineal feet at trade-practice exposures (8.25-in plank at 7-in exposure, 6.25-in at 5-in, or a custom 3-12 in) with 10% simple or 15% complex waste, 12-ft or 16-ft plank counts, housewrap rolls figured on the gross area because the wrap runs behind the opening flanges, starter strip along the wall bases, and 10-ft corner trim sticks from the corner count and height.


Squares & PlanksExposure PresetsHousewrap & Corners
Site & Sustainability

Trench Excavation Calculator (OSHA Slopes & Spoil)

Trench excavation takeoff with sides at the OSHA maximum allowable slope from 29 CFR 1926 Subpart P, Appendix B, Table B-1 (excavations under 20 ft): stable rock vertical, Type A 3/4:1, Type B 1:1, Type C 1.5:1 by the competent-person soil classification, top width at grade and trapezoidal cross-section, bank volume in cubic yards, loose spoil from representative swell presets (15% rock, 30% Type A, 25% Type B, 12% Type C) or a custom 0-60% override, 10-yd³ truckloads, and the two Subpart P safety flags: protective system required at 5 ft or deeper per 1926.652(a)(1) with the stable-rock exception, and egress within 25 ft of lateral travel at 4 ft or deeper per 1926.651(c)(2).


OSHA Slope by Soil TypeBank & Spoil VolumeSafety Flags
Site & Sustainability

Baseboard & Trim Calculator

Baseboard and trim takeoff for up to 20 rooms: installed lineal feet per room as the rectangular perimeter minus the standard 3-ft deduction per door opening (floored at zero for door-heavy closets, never negative), a 10% waste allowance for miters, copes, and splices, whole-stick purchase counts for 8-, 12-, and 16-ft stock, painter's caulk at one tube per 40 lineal feet of the INSTALLED length because waste offcuts are never caulked, and inside/outside corner counts echoed with the finish-carpentry joinery advisories — cope the inside corners so joints stay tight through seasonal movement, miter the outside corners at 45 degrees.


Room PerimetersSticks by LengthCorners & Caulk
Site & Sustainability

Flooring Calculator (Boxes, Waste & Underlayment)

Plank and laminate flooring takeoff: net floor area from up to 20 rooms minus up to 20 exclusions (kitchen islands, hearths, built-ins), boxes to buy from the coverage printed on the product carton (default 22 ft² — representative only) with a waste allowance keyed to the installation layout (10% straight, 15% diagonal, 20% herringbone/parquet), underlayment counted as 100-ft² rolls on the net area without the layout waste, an optional cost estimate from a price per box, and a chart comparing the box count across all three layouts.


Rooms & ExclusionsWaste by LayoutBoxes & Underlayment
Site & Sustainability

Grading & Drainage Slope Calculator (IRC R401.3)

Foundation drainage grade check per the IRC 2021 published text (source-verified): the ground surface must fall not fewer than 6 in within the first 10 ft of the foundation (R401.3, a 5% equivalent), impervious surfaces within 10 ft of the foundation sloped not less than 2% away from the building per the R401.3 Exception, and drains or swales where lot lines, walls, slopes, or other physical barriers prohibit the fall — pass/fail verdict with the margin in inches and the governing section reference, the required fall for any run at the governing rate with a first-10-ft caveat for longer runs and the swale/drain note for shorter ones, plus a slope converter between percent, inches per foot, and 1:N ratio with exact round-trips (5% = 0.6 in/ft = 1:20, 2% = 0.24 in/ft = 1:50).


R401.3 Check% ↔ in/ft ↔ RatioRequired Fall
Site & Sustainability

Sod & Grass Seed Calculator

Lawn establishment estimator with sod and seed modes: sod mode converts lawn area into standard 2 ft × 5 ft (10 ft²) rolls with a 5% or 10% cutting-waste allowance and into pallets at your supplier's stated coverage (300–700 ft² input, 450 default — pallet coverage varies by supplier, so it is asked, not assumed); seed mode computes pounds of grass seed from rates verified against University of Tennessee Extension W160-B "Turfgrass Establishment: Seeding" (table midpoints: Kentucky bluegrass 1.75, tall fescue 6.5, perennial ryegrass 5, hulled bermudagrass 0.75 lb per 1,000 ft²) at full rate for a new lawn or half rate for overseeding an existing thin stand, both modes adding starter-fertilizer bags at a representative 5,000 ft² per bag sized on the bare ground area rather than the waste-adjusted sod order, with the reminder that rates vary by cultivar and region — follow your seed bag and local extension.


Rolls & PalletsSeed lbs by SpeciesNew vs Overseed
Site & Sustainability

Dumpster Size Calculator (Volume & Weight)

Roll-off container sizing from a list of demolition projects: representative debris factors for roof tear-off by squares and shingle layers (1/3 yd³ + 240 lb per square per layer — the encoded 240 lb is the midpoint of the published 230–250 lb/square trade range for 3-tab, architectural runs heavier), drywall (0.2 yd³ + 220 lb) and flooring (1/3 yd³ + 150 lb) per 100 ft², deck removal (1 yd³ + 300 lb per 100 ft²), kitchen (3 yd³ + 1,500 lb) and bath (1.5 yd³ + 800 lb) demo per room, plus custom per-unit debris, with loose volume at a 15% fluff factor and weight never fluffed, checked against 10/20/30/40 yd³ containers with representative 1–4 ton rental weight allowances — one size step up when weight alone overflows, split-load guidance when heavy debris like shingles governs by weight, and a chart of the load against every container allowance, all framed as estimates to confirm with your hauler (overage fees and prohibited items vary).


Debris by ProjectVolume + Weight10–40 yd Containers