Engineering & Trades Glossary

Plain-language definitions of engineering, construction, and trades terms — each linked to the calculators, charts, and guides that use them.


Every trade has words that gatekeep its math. This glossary defines them the way the calculators use them — each term in plain language, each definition traceable to the same published standards and manufacturer data the tools are verified against.

Entries link straight to the calculators that do the arithmetic, the reference charts that hold the tabulated values, and the guides that walk through the decisions.

A

B

Bearing Capacity

The pressure a foundation soil can carry: ultimate capacity from qu = c·Nc + q·Nq + 0.5·γ·B·Nγ, divided by a factor of safety for design.

Bend Allowance

The arc of flat material a bend consumes, measured along the neutral axis: BA = θ·(π/180)·(R + K·T) — the key number in a flat-pattern layout.

Bending Moment

The internal moment a beam section must resist at a given point, found from static equilibrium and plotted as the bending-moment diagram (BMD).

Board Foot

The lumber trade’s volume unit: 1 nominal inch thick × 12 nominal inches wide × 1 foot long, so BF = thickness × width × length ÷ 12.

Bolt Preload

The clamping force a tightened bolt develops — typically 75% of proof load, reached through torque via the short-form relation T = K·F·d.

Bolt Property Class

The ISO 898-1 strength marking on metric bolts: 8.8 encodes roughly 800 MPa tensile strength with yield at 80% of it; classes run 4.6 to 12.9.

Bond Beam

A horizontally grouted course in a block wall — one course-height band of fully grouted masonry, taken off separately from the vertical-core grout.

Box Fill

The NEC 314.16 accounting of everything inside an electrical box — conductors, clamps, yokes, grounds — as volume allowances the box must equal or exceed.

BTU (British Thermal Unit)

The US customary heat unit — 1 BTU (IT) = 1,055.056 J per NIST SP 811 — with BTU/h as the rating unit for heating and cooling equipment.

Buckling

Sudden sideways instability of a compressed member at the Euler critical load Pcr = π²EI/(KL)² — a stiffness failure, not a strength failure.

C

CFM (Cubic Feet per Minute)

The US volumetric airflow unit for fans and blowers — 1 CFM = 4.719474×10⁻⁴ m³/s per NIST SP 811, about 1.699 m³/h or 0.4719 L/s.

Chain Pitch

The repeating link dimension of a roller chain, encoded in its ANSI number: the tens digits are the pitch in eighths of an inch, so #40 chain is 1/2 in.

Chip Load

Feed per tooth — the thickness of material each cutting edge removes per revolution, the bite size that milling feed rates are built from.

Coefficient of Performance (COP)

Heat delivered per unit of electrical input for a heat pump — a COP of 4.4 means a 10 kW load draws only 2.27 kW, versus COP 1 for resistance heat.

Coefficient of Thermal Expansion

The strain a material develops per kelvin, α — carbon steel grows about 12×10⁻⁶ of its length per degree, driving ΔL = α·L·ΔT movement checks.

Common Rafter

The straight sloped member running from wall plate to ridge — laid out from run and pitch, and span-checked on its horizontal projection, not its length.

Compound Miter

A cut that swings the miter table and tilts the blade at once — how crown molding is cut lying flat, e.g. 31.62° miter with 33.86° bevel for a square corner.

Compressive Strength (f′c / fck)

The specified 28-day strength of concrete under compression — f′c from cylinder tests in US practice, fck cylinder/cube pairs in Eurocode classes.

Concrete Cover

The clear concrete thickness between a rebar surface and the face of the member — it reduces effective depth and directly drives crack spacing.

Concrete Masonry Unit (CMU)

The hollow concrete block walls are laid from — conventional two-core units in 6, 8, 10, and 12 in widths whose cells take reinforcement and grout.

Conduit Fill

The fraction of a raceway’s internal area occupied by cables — capped at 40% for more than two conductors in conduit per NEC Chapter 9.

Continuous Load (NEC)

An NEC load expected to run at maximum current for three hours or more — conductors and standard breakers must be sized at 125% of it.

Cord (Firewood)

The legal firewood unit per NIST Handbook 130: the wood contained in 128 cubic feet when ranked and well stowed — the only basis sellers may quote.

Cut and Fill

Balancing excavation against embankment along an alignment: integrate the cut and fill areas between survey stations, then net them for surplus or borrow.

Cutting Speed (SFM)

The surface speed between cutting edge and workpiece, in surface feet per minute or m/min — the tooling number spindle RPM is computed from.

D

E

F

G

H

I

K

L

M

N

O

P

R

S

Section Modulus

A cross-section property, S = I/c, that converts a bending moment directly into extreme-fibre bending stress; the primary number for shortlisting beams.

Sensible Heat

The part of a cooling load that changes air temperature — envelope, solar, lighting, equipment, and people — as opposed to the moisture-removal part.

Shear Force

The net transverse force acting on a beam cross-section, taken positive when the resultant to the left of the cut acts upward; plotted as the SFD.

Sheet Metal Gauge

A material-specific thickness number where higher means thinner: 16 gauge is 0.0598 in steel, 0.0635 galvanized, 0.0625 stainless, 0.0508 aluminum.

Shielding Gas

The gas envelope that protects a molten weld puddle from air — bottled CO₂/argon mixes in MIG, inert argon in TIG, flux-generated in stick welding.

Slump

The workability specification for fresh concrete, stated in mm (e.g. 75–100 mm) — one of the design inputs that sets mixing water in ACI 211.1.

Specific Heat Capacity

The heat that raises a unit mass of fluid one degree — cp ≈ 4.186 kJ/kg·K for water — linking thermal load to flow through Q = m·cp·ΔT.

Spring Angle

The angle crown molding leans off the wall — 38° for standard US 52/38 stock, 45° and 52° for other profiles — the input every compound cut starts from.

Square (Roofing)

The roofing trade’s unit of area: 1 square = 100 sq ft of roof surface, the basis shingle bundles, coverage, and estimates are all quoted in.

Static Pressure

The pressure a fan or pump must develop against a duct or pipe system’s resistance — straight-run friction plus fitting losses plus static head.

Surcharge Load

Extra load sitting on retained or founding soil — a uniform surcharge q adds a rectangular wall-pressure block K·q·H acting at mid-height.

Swell Factor

How much excavated soil bulks past its bank volume — 100 yd³ in place at 25% swell loads out as roughly 125 loose cubic yards of spoil.

T

Take-Up (Conduit Bending)

The bender deduct for a 90° stub-up — the length the bend itself consumes — subtracted from the stub height to place the mark: 5″ for 1/2″ EMT, 6″ for 3/4″.

Tap Drill Size

The hole diameter drilled before tapping an internal thread, from the handbook rule drill = major − 1.29904 × pitch × %engagement ÷ 100.

Tensile Strength (Ultimate)

The ultimate stress a material is rated for — the figure metric bolt classes encode: an 8.8 bolt carries roughly 800 MPa tensile, yielding at 80% of it.

Tensile Stress Area

The effective cross-section a threaded fastener breaks across — smaller than the shank, larger than the minor-diameter area — that bolt ratings are built on.

Thermal Bridging

Extra heat loss where a junction or conductive element bypasses the insulation — quantified per metre as the psi-value under EN ISO 10211.

Thread Engagement Length

The depth of thread actually carrying load in a tapped joint — sized so the bolt breaks before either thread strips, per the FED-STD-H28 formulas.

Thread Pitch

The spacing of a metric thread in millimetres — the second number in M10×1.5 — with inch threads quoting its reciprocal as threads per inch.

Threads Per Inch (TPI)

How inch threads state their pitch: the count of thread crests per inch — a 1/4-20 UNC bolt has 20, and its pitch is the reciprocal, 1/20 inch.

Tolerance Class (ISO 286)

An ISO 286 designation such as H7 or p6 that fixes a pair of limit deviations for a nominal size, so a fit callout fully determines clearance or interference.

Ton of Refrigeration

The cooling rate that melts one US short ton of ice in 24 hours — standardized as exactly 12,000 BTU/h = 3,516.853 W, about 3.517 kW.

Torque

A moment — force times lever arm — in N·m or ft·lb (1 ft·lbf = 1.355818 N·m), tied to shaft power through P = T × ω.

Total Dynamic Head

The total energy a pump must add to the fluid at design flow — static lift plus friction losses plus velocity head, expressed in metres of head.

Tributary Area

The patch of floor or deck whose load drains to one supporting member — tributary width times spacing — used to compute post and footing loads.